ASTM D3426用脈沖波法測定固體電絕緣材料電介質擊穿電壓及抗電強度標準試驗方法

放大字體  縮小字體 發布日期:2012-02-10   瀏覽次數:357  分享到: 分享到騰訊微博
ASTM D3426用脈沖波法測定固體電絕緣材料電介質擊穿電壓及抗電強度標準試驗方法
ASTM D3426 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials Using Impulse Waves
ASTM D3426用脈沖波法測定固體電絕緣材料電介質擊穿電壓及抗電強度標準試驗方法
Insulating materials used in high-voltage equipment may be subjected to transient voltage stresses, resulting from such causes as nearby lightning strokes. This is particularly true of apparatus such as transformers and switchgear used in electrical-power transmission and distribution systems. The ability of insulating materials to withstand these transient voltages is important in establishing the reliability of apparatus insulated with these materials.
Transient voltages caused by lightning may be of either positive or negative polarity. In a symmetrical field between identical electrodes, the polarity has no effect on the breakdown strength. However, with dissimilar electrodes there may be a pronounced polarity effect. It is common practice when using dissimilar electrodes, to make negative that electrode at which the higher gradient will appear. When asymmetrical electrodes are used for testing materials with which the tester has no previous experience or knowledge, it is recommended that he make comparative tests with positive polarity and negative polarity applied to the higher gradient, or smaller electrode, to determine which polarity produces the lower breakdown voltage.
The standard wave shape is a 1.2 by 50-μs wave, reaching peak voltage in approximately 1.2 μs and decaying to 50 % of peak voltage in approximately 50 μs after the beginning of the wave. This wave is intended to simulate a lightning stroke that may strike a system without causing failure on the system.
For most materials, the impulse dielectric strength will be higher than either its power frequency alternating voltage or its direct voltage dielectric strengths. Because of the short time involved, dielectric heating and other thermal effects are largely eliminated during impulse testing. Thus, the impulse test gives values closer to the intrinsic breakdown strength than do longer time tests. From comparisons of the impulse dielectric strength with the values obtained from longer time tests, inferences may be drawn as to the modes of failures under the various tests for a given material. Appendix X1 of Test Method D 149 should be referred to for further information on this subject.
1. Scope
1.1 This test method covers the determination of dielectric strength of solid electrical insulating materials under simulated-lightning impulse conditions.
1.2 Procedures are given for tests using standard 1.2 by 50 s full-wave impulses.
1.3 This test method is intended for use in determining the impulse dielectric strength of insulating materials, either using simple electrodes or functional models. It is not intended for use in impulse testing of apparatus.
1.4 This test method is similar to IEC Publication 243-3. All procedures in this test method are included in IEC 243-3. Differences between this test method and IEC 243-3 are largely editorial.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precaution statements are given in Section 9.

2. Referenced Documents (purchase separately)
ASTM Standards
D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
D374 Test Methods for Thickness of Solid Electrical Insulation
D2413 Test Methods for Preparation of Insulating Paper and Board Impregnated with a Liquid Dielectric
American National Standard
C68.1 Techniques for Dielectric Tests (IEEE Standard No. 4)
IEC Standard
Pub243-3 Methods of Test for Electric Strength of Solid Insulating Materials--Part 3: Additional Requirements for Impulse Tests
Index Terms
dielectric breakdown; dielectric breakdown criteria; dielectric breakdown voltage; dielectric strength; full-impulse-voltage wave; impulse dielectric strength; impulse generator; impulse waves; lightning strokes; peak value; simulated-lightning impulse; solid insulating material; virtual front time; virtual origin; virtual peak value; virtual time to half-value
 

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 日日噜噜夜夜爽爽 | 欧美叉叉叉BBB网站 欧美成人AAA毛片 | 国产成人精品视频在放 | 麻豆精品久久久 | 亚州aⅴ中文aⅴ无码aⅴ | 欧美黑人添添高潮A片视频 欧美黑人性暴力猛交喷水 欧美黑人性暴力猛交喷水黑人巨大 | 亚洲国产电影院之毛片 | 亚洲不卡av不卡一区二区 | 亚洲日本三级 | 亚洲欧洲无码av电影在线观看 | 国产精品久久久久免费观看 | 国产精品高潮呻吟AV久久黄 | 国产欧美一区二区三区久久 | 丝袜长腿aⅴ | 一区二区三区国产好的精 | 综合网日日夜夜7799 | 人妻丝袜无码国产一区 | 亚洲中文字幕精品久久久久久直播 | 亚洲国产美女精品久久久久∴ | 亚洲精品午夜va久久成人 | 精品久久无码中文字幕 | 国产成人亚洲影院在线播放 | 中国av在线播放 | 五月色综合网天天综合网 | 99久久99久久久精品齐齐 | 国产精品人人爽人人做我的可爱 | 无码一区二区三区网站 | 97久久精品无码一区二区 | 91麻豆精品视频 | 自拍偷拍+中文字幕 | 真实国产乱子伦视频对白 | 日韩人妻系列无码专区三级 | 日韩欧美综合视频在线 | 久久精品国产亚洲AV成人 | 日韩欧美激情国产一区二区蜜 | 中文无遮挡国产日韩综合一区二区 | 人妻精品久久久久中文字幕一冢本完整版在线观看 | 欧美日韩国产综合一 | 99久久国产露脸精品国产麻豆 | 亚洲国产精品va在线观看香蕉 | 国产视频二区午夜福利一二区 |