ASTM E108屋頂覆蓋物防火試驗標準試驗方法

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):424  分享到: 分享到騰訊微博
ASTM E108屋頂覆蓋物防火試驗標準試驗方法
ASTM E108  Standard Test Methods for Fire Tests of Roof Coverings
ASTM E108屋頂覆蓋物防火試驗標準試驗方法
The test methods described herein are intended to provide a basis for relative comparison of roof coverings. The test methods include simulated fire exposure to the outside of the roof coverings, and, where applicable, a determination as to whether the fire performance characteristics of the roof coverings will be adversely affected by prolonged exposure to rain.
These test methods measure the surface spread of flame and the ability of the roof covering material or system to resist fire penetration from the exterior to the underside of a roof deck under the conditions of exposure.
These test methods also provide criteria to determine if the roof covering material will develop flying burning material, identified as flying brands, when subjected to a 12-mph (5.3-m/s) wind during the simulated fire exposure tests.
These test methods do not necessarily illustrate the expected performance of roof coverings under all actual fire conditions, but they do provide a basis for comparing roof covering materials when subjected to fire sources that are described herein.
These test methods do not provide any basis for determining the fire resistance characteristics when exposed to a fire originating in the building to which the roofing material is applied.
The test methods described herein involve calibrating the test equipment using a calibration deck inclined at a slope of 5 in. per horizontal ft (0.416:1). The tests described herein are performed on test decks inclined at slopes up to and including 5 in. per horizontal ft. The severity of the test exposure decreases as the slope of the test deck decreases below 5 in. per horizontal ft.
1. Scope
1.1 This fire-test-response standard covers the measurement of the relative fire characteristics of roof coverings under simulated fire originating outside the building. It is applicable to roof coverings intended for installation on either combustible or noncombustible decks when applied as intended for use. The following test methods are included:
1.1.1 Intermittent flame exposure test.
1.1.2 Spread of flame test.
1.1.3 Burning brand test.
1.1.4 Flying brand test.
1.1.5 Rain test.
1.2 Three classes of fire test exposure are described:
1.2.1 Class A Tests are applicable to roof coverings that are effective against severe test exposure, afford a high degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.
1.2.2 Class B Tests are applicable to roof coverings that are effective against moderate test exposure, afford a moderate degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.
1.2.3 Class C Tests are applicable to roof coverings that are effective against light test exposure, afford a light degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled laboratory conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.

2. Referenced Documents (purchase separately)
ASTM Standards
D225 Specification for Asphalt Shingles (Organic Felt) Surfaced With Mineral Granules
D226 Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
D227 Specification for Coal-Tar-Saturated Organic Felt Used in Roofing and Waterproofing
D312 Specification for Asphalt Used in Roofing
D450 Specification for Coal-Tar Pitch Used in Roofing, Dampproofing, and Waterproofing
D1227 Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
D2178 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
D2626 Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet Used in Roofing
D2898 Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
D3018 Specification for Class A Asphalt Shingles Surfaced with Mineral Granules
D3158 Discontinued 1984; Specification for Asphalt Saturated and Coated Organic Felt Used in Roofing
D3378 Discontinued 1985; Specification for Asphalt-Saturated and Coated Asbestos Felt Base Sheet Used in Roofing
D3462 Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules
D4442 Test Methods for Direct Moisture Content Measurement of Wood and Wood-Base Materials
D4444 Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters
UL Standards
NFPA Standards
NFPA256 Tests of Roof Coverings
Index Terms
burning brands; classification; flying brand; intermittent flame; rain test; roof coverings; roof deck; spread of flame: Burning brand test; Fire testing--building materials; Flying brand test; Heating tests--building products; Intermittent flame exposure test; Rain; Roofing materials/applications; Weathering (building materials/applications) ;

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權,不得復制、轉(zhuǎn)載、摘編或利用其它方式應用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網(wǎng)站首頁 | 廣告服務 | 關于我們 | 聯(lián)系方式 | 服務協(xié)議 | 版權聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 男男女女爽爽爽视频免费 | 国精产品一品二品国精在线观看 | 国产高潮流白浆喷水免费动漫 | 附近约妓女软件 | 亚洲AV成人无码一二三在线观看 | 精品无码国产av一区二区 | 亚洲人成网线在线播放不卡 | 久久精品国产亚洲av大全 | 91精品国产自产91精品 | 大胆国模一区二区三区伊人 | 亚洲五月丁香综合视频 | 一本道久久爱88AV俺也去 | 日本aⅴ欧美激情在线 | 国产日产亚洲系列最新 | 成人国产在线看不卡 | 国产美女极度色诱视频www | 最新国产真实在线视频 | 无码欧美黑人又大又 | 性饥渴的农村熟妇 | 在线观看的资源视频火影忍者 | 麻豆成人传媒一区二区 | 精品人妻伦一二三区久久AAA片 | 亚洲美日韩av中文字幕无码 | 久久久精品中文字幕麻豆发布 | 欧美日韩国产免费一区二 | 99久久精品国产成人综合 | 好硬啊进去太深了A片 | 亚洲国产欧美一区二区欧美 | 综合一区无套内射中文字幕 | 亚洲欧美色a片一区二区三区 | 欧美日韩精品一区二区三区视频 | 久久久久国产一级毛片高清版国产 | 免费观看又色又爽又黄的 | 国产三级精品三级在线专区 | 76少妇精品导航 | 中文字幕无线码一区二区三区 | 国产日产欧产美韩系列使用方法 | A片好大好紧好爽视频免费 A片娇妻被交换粗又大又硬V | 亚洲国产精品国自产拍久久 | 伊人色综合久久天天伊人 | 国产成人久久精品一区二区三 |