ASTM E1355 火焰模型預測能力評定指南

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:57  分享到: 分享到騰訊微博
ASTM E1355 火焰模型預測能力評定指南
ASTM E1355 Standard Guide for Evaluating the Predictive Capability of Deterministic Fire Models
ASTM E1355 火焰模型預測能力評定指南
The process of model evaluation is critical to establishing both the acceptable uses and limitations of fire models. It is not possible to evaluate a model in total; instead, this guide is intended to provide a methodology for evaluating the predictive capabilities for a specific use. Validation for one application or scenario does not imply validation for different scenarios. Several alternatives are provided for performing the evaluation process including: comparison of predictions against standard fire tests, full-scale fire experiments, field experience, published literature, or previously evaluated models.
The use of fire models currently extends beyond the fire research laboratory and into the engineering, fire service and legal communities. Sufficient evaluation of fire models is necessary to ensure that those using the models can judge the adequacy of the scientific and technical basis for the models, select models appropriate for a desired use, and understand the level of confidence which can be placed on the results predicted by the models. Adequate evaluation will help prevent the unintentional misuse of fire models.
5.3 This guide assumes understanding of the use and limitations of the model under analysis as detailed in E1895.
This guide is intended to be used in conjunction with other guides under development by Committee E05. It is intended for use by:
Model Developers—To document the usefulness of a particular calculation method perhaps for specific applications. Part of model development includes identification of precision and limits of applicability, and independent testing.
Model Users—To assure themselves that they are using an appropriate model for an application and that it provides adequate accuracy.
Developers of Model Performance Codes—To be sure that they are incorporating valid calculation procedures into codes.
Approving Officials—To ensure that the results of calculations using mathematical models stating conformance to this guide, cited in a submission, show clearly that the model is used within its applicable limits and has an acceptable level of accuracy.
Educators—To demonstrate the application and acceptability of calculation methods being taught.
This guide is not meant to describe an acceptance testing procedure.
The emphasis of this guide is numerical models of fire evolution.
The precision of a model refers to the deterministic capability of a model and its repeatability.
The accuracy of a model refers to how well the model replicates the evolution of an actual fire.
1. Scope
1.1 This guide provides a methodology for evaluating the predictive capabilities of a fire model for a specific use. The intent is to cover the whole range of deterministic numerical models which might be used in evaluating the effects of fires in and on structures.
1.2 The methodology is presented in terms of four areas of evaluation:
1.2.1 Defining the model and scenarios for which the evaluation is to be conducted,
1.2.2 Verifying the appropriateness of the theoretical basis and assumptions used in the model,
1.2.3 Verifying the mathematical and numerical robustness of the model, and
1.2.4 Quantifying the uncertainty and accuracy of the model results in predicting of the course of events in similar fire scenarios.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 This guide assumes understanding of the use and limitations of the model under analysis as detailed in Guide E1895.
1.5 This fire standard cannot be used to provide quantitative measures.

2. Referenced Documents (purchase separately)
ASTM Standards
E176 Terminology of Fire Standards
E603 Guide for Room Fire Experiments
E1472 Guide for Documenting Computer Software for Fire Models
E1591 Guide for Obtaining Data for Deterministic Fire Models
E1895 Guide for Determining Uses and Limitations of Deterministic Fire Models
International Standards Organization Standards
ISO16730(2008) Fire safety engineering - Assessment, verification and validation of calculation methods
Index Terms
evaluation; fire model; sensitivity; validation; Fire analysis models; Fire testing--building materials; Predictive capability; Validation;


  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2012-2014 FIRETC.COM All Rights Reserved ? 在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 亚洲精品欧美二区三区中文字幕 | 亚洲欧洲精品成人久久曰 | 无码国产伦精品一区二区三区视频 | 国产亚洲区 | 欧美午夜a级限制福利片 | 欧美日本在线一区二区三区 | 果冻传媒最新视频在线观看 | 无码人妻精品一区二区三区蜜桃 | 精品视频一区二区三三区四区 | 久久久国产精品免费A片蜜芽广 | 毛片男人黑人巨大无码中文字幕无码 | nba直播在线观看高清免费 | 亚洲成 人图片综合网 | 日本夜爽爽一区二区三区 | 欧美成精品色网在线观看 | 国产国语亲子伦亲子 | 亚洲中文字幕久久精品蜜桃天天91中国18女人入口 | 精品少妇一区二区三区A片 精品少妇一区二区三区免费观 | 免费看又色又爽又黄的国产软件 | 中文字幕一区二区不卡在线 | 国产日韩久久久久无码精品 | 国产狂喷潮在线观看 | 亚洲日韩欧美一区二区在线 | 亚洲午夜精品一级在线 | 亚洲国产成人精品久久久久av无码综合色 | 国产无人区码卡二卡三卡免费 | 国精产品一区二区三区有限公司 | 欧美日韩电影在线观看 | 日本精品mv在线观看 | 亚洲地址一地址二地址三 | 在线日本视频 | 亚洲精品无码av人在线观看国产 | 日本无码人妻精品一区二区视频 | 亚洲一区二区三区免费观看 | 日韩欧美在线观看视频 | 亚洲 日韩 欧美 制服 无码 | 成人午夜福利视频后入 | 国产日产成人免费视频在线观 | 午夜成人理论无码电影在线播放 | 亚洲www.999| 人妻中文无码久热丝袜 |