ASTM B784 絕緣電纜用改進的同芯絞捻銅導線標準規范

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:170  分享到: 分享到騰訊微博
ASTM B784 絕緣電纜用改進的同芯絞捻銅導線標準規范
ASTM B 784 Standard Specification for Modified Concentric-Lay-Stranded Copper Conductors for Use in Insulated Electrical Cables
ASTM B784 絕緣電纜用改進的同芯絞捻銅導線標準規范
This specification covers bare modified concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated electrical cables. These conductors shall be constructed with a central core consisting of not more than seven wires, surrounded by one or more layers of helically laid wires. For the purposes of this specification, conductors are classified as Class B modified, class C modified, and Class D modified. The conductors shall meet the prescribed construction requirements such as number of wires and diameter. Welds and brazes may be made in rods or in wires prior to final drawing. Welds and brazes may be made in the finished individual wires composing the conductor, but shall not be closer together than prescribed distance. Tests for the electrical properties of wires composing conductors made from soft or annealed copper wire, bare or coated, shall be made before stranding. Tests for the physical properties of these materials may be made upon the wires before stranding or upon wires removed from the complete stranded conductor.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers bare modified concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated electrical cables. These conductors shall be constructed with a central core consisting of not more than seven wires, surrounded by one or more layers of helically laid wires.
1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Note 1 and Note 2):
1.2.1 Class B Modified—Conductors to be insulated with various materials such as rubber, paper, and crosslink polyethylene.
1.2.2 Class C Modified and Class D Modified—Conductors where greater flexibility is required than is provided by Class B Modified conductors.
1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining the values from the two systems may result in non- conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. for conductor sizes designated by SI units only, the requirements are stated or derived in SI units.
1.3.1 For density, resitivity and temperature, the values stated in SI units are to be regarded as standard.
Note 1—The significant differences in this specification from Specification B 8 are as follows: (1) The central core is permitted to contain up to seven wires drawn into the assembly with an infinite length of lay while Specification B 8 permits only one, and (2) The construction is applicable only to stranded assemblies of 19 or more wires.

2. Referenced Documents (purchase separately)
 ASTM Standards
B3 Specification for Soft or Annealed Copper Wire
B8 Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
B33 Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
B189 Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical Purposes
B263 Test Method for Determination of Cross-Sectional Area of Stranded Conductors
B354 Terminology Relating to Uninsulated Metallic Electrical Conductors
Other Standard
NBS Handbook 100
Index Terms
copper conductors for insulated wires; copper modified concentric-lay-stranded; electrical copper conductors;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 亚洲成a人片在线观看天堂无码 | 亚洲性人人天天夜夜摸福利 | 欧美亚洲另类丝袜自拍动漫 | 久久久人妻无码A片一区二区三区 | 亚洲成人中文字幕 | 欧美福利视频 | 国产精品久久久久久日本一道 | 精品麻豆一卡2卡三卡 | 91国内免费久久久久久久久久 | 免费观看成人欧美www色 | 98精产国品一二三产区区 | 麻豆A片爽爽歪歪爽爽视频看看 | 国产日韩在线 | 亚洲精品国产高清不卡在线 | 无码调教完整版老师中文字幕97无码免费人妻 | 国产一级无码av片在线观看 | 人与禽一级一级毛片 | 欧美日韩1区 | 国产无码免费的中文字幕 | 无码日本被黑人强伦姧人 | 精品少妇人妻av免费久久洗澡 | 亚洲av无码一区二区三区天堂 | 91久久国产综合精品女同国语 | 无码熟熟妇丰满人妻啪啪软件 | 久久精品国产亚洲av高清漫画 | 国产福利萌白酱在线观看网站 | 重口老熟女露脸 | 韩国主播精品一区二区三区 | 亚洲VA欧美VA人人爽成 | 日韩内射激情视频在线播放免费 | 国产传媒精品1区2区3区国语在线观看 | 另类老妇性bbwbbw | 亚洲一区二区在线观看不卡 | 无码少妇丰满熟妇一区二区 | 亚洲综合伦理 | 日韩网红少妇无码视频香港 | 91精品国产综合精品久久久精品 | 久久最喜欢的中文字幕 | 日韩情欲综合福利久久电影 | 欧美国产成人久久精品久久精品亚洲欧美日韩久久 | 东京热无码人妻中文 |